HPE Aruba Networking CX 6200F 48G Class 4 PoE 4SFP 740W Switch S0M85AR RENEW
HPE Aruba Networking CX 6200F 48G Class 4 PoE 4SFP 740W Switch (S0M85A) | |
Description | 48x ports 10/100/1000BASE-T Class 4 PoE Ports, supporting up to 30W per port |
Power supplies | Fixed power supply Up to 740W of Class 4 PoE Power |
Fans | Fixed fans |
Physical characteristics | |
Dimensions | (H) 4.37 cm x (W) 44.25 cm x (D) 32.66 cm (1.72" x 17.42" x 12.86") |
Configuration Weight | 5.13 kg (11.32 lbs) |
Additional Specifications | |
CPU | Quad Core ARM CortexTM A72 @ 1.8GHz |
Memory and Flash | 8 GB DDR4 16 GB eMMC |
Packet Buffer | 6 MB Packet Buffer Memory |
Performance | |
Model Switching Capacity | 176 Gbps |
Model Throughput Capacity | Up to 130.9Mpps |
Average Latency (LIFO-64-bytes packets) | 1Gbps: 3.2µSec 10Gbps: 1.46µSec |
Stack Size | 8 members |
Max. Stacking Distance | Up to 10 kms with long range transceivers |
Stacking Bandwidth | 40 Gbps |
Switched Virtual Interfaces (dual stack) | 256 |
IPv4 Host Table (ARP) | 8,192 |
IPv6 Host Table (ND) | 8,192 |
IPv4 Unicast Routes | 2,048 |
IPv6 Unicast Routes | 1,024 |
MAC Table Capacity | 32,768 |
IGMP Groups | 1,024 |
MLD Groups | 1,024 |
IPv4/IPv6/MAC ACL Entries (ingress) | 5,120/ 1,280/5,120 |
IPv4/IPv6/MAC ACL Entries (egress) | 2,048/512/2,2048 |
Environment | |
Operating Temperature | 32°F to 113°F (0°C to 45°C) up to 5,000 ft derate -1°C for every 1000 ft from 5,000 ft to 10,000 ft. |
Operating Relative Humidity | 5% to 95% @ 104°F (40°C) non-condensing |
Non-Operating | -40°F to 158°F (-40°C to 70°C) up to 15000 ft |
Non-Operating Storage Relative Humidity | 5% to 95% @ 149°F (65°C) non-condensing |
Max Operating Altitude | 10,000 feet (3.048 km) Max |
Max Non-Operating Altitude | 15,000 feet (4.6 km) Max |
Acoustic | Sound Power, LWAd = 5.3 Bel Sound Pressure, LpAm (Bystander) = 36.5 dB |
Primary Airflow | Front and side to back |
Electrical Characteristics | |
Frequency | 50Hz/60Hz |
AC Voltage | 100V-120V/200V-240V |
Current | 10.3A/5.0A |
80plus.org Certification | 80plus Gold |
Maximum heat dissipation BTU/hr and kj/hr info needed | 205 BTU/hr 216 kj/hr |
Power Consumption (230 VAC) | Hibernation (0 rpm fan): 12W Idle: 42W 100% Traffic Rate: 60W |
Safety | Europe: EN 62368-1:2014+A11:2017 EN 62368-1:2020+A11:2020 UK: BS EN 62368-1:2014 + A11:2017 2nd Ed BS EN 62368-1:2020 + A11:2020 3rd Ed UL 62368-1, 3rd Ed., CAN/CSA C22.2 No. 62368-1:19, 3rd Ed. IEC 62368-1:2014 2nd Ed. IEC 62368-1: 2018 3rd Ed. CNS-15598-1:2020 GB 4943.1:2022 |
Emissions | Europe: EN 55032:2015 +A11:2020, Class A EN 61000-3-2:2019 EN 61000-3-3:2013 FCC 47 CFR part 15B: Class A ICES-003 Issue 7: 2020, Class A VCCI-CISPR 32, Class A CISPR 32: 2016, Class A AS/NZS CISPR 32: 2015, Class A GB/T 9254.1-2021, Class A CNS 15936: 2020, Class A KS C 9832 |
Lasers | EN 60825-1:2014 / IEC 60825-1:2014 Class 1 Class 1 Laser Products / Laser Klasse 1 (Applicable for accessories - Optical Transceivers only) |
Immunity | |
Generic | CISPR 35: 2016 |
EN | EN 55035:2017 +A11:2020 |
ESD | IEC 61000-4-2 |
Radiated | IEC 61000-4-3 |
EFT/Burst | IEC 61000-4-4 |
Surge | IEC 61000-4-5 |
Conducted | IEC 61000-4-6 |
Power frequency magnetic field | IEC 61000-4-8 |
Voltage dips and interruptions | IEC 61000-4-11 |
Harmonics | IEC / EN 61000-3-2 |
Flicker | IEC / EN 61000-3-3 |
RoHS | EN 63000:2018 / IEC 63000:2018 |
Mounting and Enclosure | Mounts in an EIA-standard 19 in. Telco rack or equipment cabinet. Horizontal surface mounting only. 2-post rack kit included. |
.